Fluke DSX 5000Qi 1GHz DSX Series Cable Analyzer with OLTS Quad Fiber Inspection

The DSX-5000 CableAnalyzer improves the efficiency of copper certification with unmatched speed for testing Cat 6A and Class FA while meeting draft IEC Level V – the most stringent accuracy requirement. The ProjX Management System helps ensure jobs are done correctly the first time and helps tracks progress from set-up to systems acceptance. Versiv platform supports modules for fiber testing (Both OLTS and OTDR) and Wi-Fi Analysis and Ethernet troubleshooting. The platform is easily upgradeable to support future standards. Troubleshoot faults faster with the Taptive user interface which graphically displays the source of failures including crosstalk, return loss and shield faults. Analyze test results and create professional test reports using LinkWare™ Management Software.

Fluke Networks' DSX-5000 CableAnalyzer is Intertek (ETL) Verified in accordance with the IEC-61935-1 specifications for accuracy Level IV, and draft accuracy Level V, and in accordance with the ANSI/TIA-1152 specifications for Level IIIe.

Specifications

Cable Types
Shielded and Unshielded Pair LAN Cabling TIA Category 3, 4, 5, 5e, 6, 6A: 100 Ω ISO/IEC Class C, D, E, EA, F, and FA: 100 Ω and 120 Ω
Standard Link Interface Adapters
Permanent Link Adapters Plug type: shielded RJ45
Optional Plug type: Tera
Channel Adapters Jack type: shielded RJ45
Optional Jack type: Tera
Test Standards
TIA Category 3, 4, 5, 5e, 6, 6A per TIA 568-C.2
ISO/IEC Class C and D, E, Ea, F, FA certification per ISO/IEC 11801:2002 and amendments
Maximum Frequency 1200 MHz
General Specifications
Speed of Autotest Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds
Full 2-way Autotest of Category 6A/Class EA: 10 seconds
Support Test Parameters (The selected test standard determines the test parameters and the frequency range of the tests) Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input Protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display 5.7 in LCD display with a projected capacitance touchscreen
Case High impact plastic with show absorbing overmold
Dimensions Main Versiv unit with DSX-5000 module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
Weight Main Versiv unit with DSX-5000 module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote Lithium ion battery pack, 7.2 V
Typical battery life 8 hours
Charge time* Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.
Languages supported English, French, German, Spanish, Portuguese, Italian, Japanese, and Simplified Chinese
Calibration Service center calibration period is 1 year
Environment Specifications
Operating Temperature 32 to 113°F (0 to 45°C)
Storage Temperature -4 to 122°F (-20 to 50°C)
Operating relative humidity 0% to 90%, 32 to 95°F (0 to 35°C)
0% to 70%, 95 to 113°F (35 to 45°C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapter
Safety CSA 22.2 No. 61010, IEC 61010-1 2nd Edition + Amendments 1, 2
Operating altitude 13,123 ft (4,000 m)
EMC EN 61326-1
Performance Specifications
Category 6A/Class EA test modes (or lower link categories) DSX-5000 CableAnalyzer modules exceed with Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.
Class FA test modes DSX-5000 CableAnalyzer modules exceed Level V requirements as in the draft 4th edition of IEC 61935-1.
Length of Twisted Pair Cabling Without Remote
Range 800 m (2600 ft)
Resolution 0.1 m or 1 ft
Accuracy ± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m
Length of Twisted Pair Cabling With Remote
Range 150 m (490 ft)
Resolution 0.1 m or 1 ft
Accuracy ± (0.3 m + 2 %)
Propagation Delay Without Remote
Range 4000 ns
Resolution 1 ns
Accuracy ± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns
Propagation Delay With Remote
Range 750 ns
Resolution 1 ns
Accuracy ± (2 ns + 2 %)
Delay Skew
Range 0 ns to 100 ns
Resolution 1 ns
Accuracy ± 10 ns
DC Loop Resistance Test
Range 0 Ω to 540 Ω
Resolution 0.1 Ω
Accuracy ± (1 Ω + 1 %)
Overload recovery time

Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.

 Included:

  • 1 Versiv Mainframe & Remote
  • (2) DSX-5000 CableAnalyzer Modules
  • (2) CertiFiber Quad OLTS Modules
  • Set of CAT 6A/Class EA Permanent Link Adaptors
  • Set of CAT 6A/Class EA Channel Adaptors
  • (2) Headsets, (2) Handstraps, (2) Shoulder Straps
  • Large Carry Case, USB Interface Cable
  • LinkWare Software CD
  • AxTalk Software CD
  • User Manual CD
  • (2) AC Chargers
  • (2) Universal Couplers
  • (2) AxTalk Terminators
  • USB Video Inspection Probe w/ 4 Tips
  • (2) OneClick Cleaner (1.25/2.50 mm)
  • (2) LC/LC Simplex Adaptors
  • SC/LC EF-Compliant MM TRC Kit 50 µm
  • SC/LC SM TRC Kit
  • TRC Carry Case
  • Statement of Calibration and Getting Started Guides

Find Similar Products by Category


Write your own product review

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!


Add to Wish List

Click the button below to add the Fluke Networks DSX-5000QI Cable Analyzer to your wish list.

You Recently Viewed...