Castle GA2006H Vexo Tri-Axial Hand Arm Vibration Meter



Castle GA2006H Vexo Tri-Axial Hand Arm Vibration Meter
This is the GA2006H Vexo Tri-Axial Hand Arm Vibration Meter which measures vibration levels and reduces your risk of hand-arm vibration syndrome (HAVS). It is a powerful meter capable of accurate measurements whilst remaining simple to use. The meter has been designed with only 3 operational buttons making it possible to take measurements with ease which can be easily read on the large colour display or stored for later download to Vibdata Vibration Analysis Software. A rechargeable battery pack ensures that your vibration meter is ready and waiting whenever you need it. The meter can be used anywhere and effectively measure vibration exposure to ensure HAVS doesn't become a problem with your workforce and it has been built to be tough, in a small and rugged case.
Vexo H Features: 
Tri-axial vibration meter
Fully compliant with ISO 8041 : 2005
Large dynamic range
Re-chargeable battery pack and charger
Large 'Flash' memory
Rugged accelerometer and cable
Large colour display
Only 3 operational buttons for simple use
Castle Sonus GA116L Class 1 Logging Sound Level Meter
This is the Sonus GA116L Class 1 Logging Sound Level Meter and it brings simplicity and power to the world of Noise at Work and Environmental sound monitoring. From basic non-logging sound level meters to combined sound and dose meters with time and date stamped data logging capability. It is a full data logging, integrating sound and noise exposure meter (dosemeter) which has been designed for both Environmental Sound Monitoring and Noise at Work assessments.
Specifications  :
Castle GA2006H Vexo Tri-Axial Hand Arm Vibration Meter
  • Instrument Standards 
    • ISO 8041 : 2005 Human Response to Vibration
    • ISO 5349 : 2001 Measurement and evaluation of human exposure to hand-transmitted vibration
  • Range (Integration = Acceleration) 
    • Low: 0.05 - 200.0m/s-2 / 0.005 - 20.4g
    • High: 0.50 - 2000.0m/s-2 / 0.05 - 204.0g
  • Measurement Channels One
  • Parameters Acceleration: Arms, Aeq, Amax, Peak, Vector Sum, HSE Exposure Points, EAV and ELV
  • Linear Operating Range 72 dB
  • Frequency Weighting WH - Hand Arm Filter
  • Memory Flash memory storing up to 992 recordings
  • Transducer Castle KD1010, 10mV/g
  • Noise Floor 
    • <0.002 m/s-2 - Low Range
    • <0.020 m/s-2 - High Range
  • Display Full Colour Graphic OLED Display (160 x 128)
  • Batteries NiMH re-chargeable cell pack- Typically 10 hours continuous use
  • Connections
    • Input: 3.5mm Stereo Jack Socket
    • AC Output: 4 Pole 3.5mm Jack Socket
    • Download: USB Micro B (Cable Supplied)
    • Recharge: DC Socket (Charger & Cable Supplied)
  • Languages English UK, English US, Chinese, French, German, Italian, Portuguese Brazilian, Russian, Spanish
  • Environmental Temperature Operating Range: -10 to + 50ºC
  • Humidity: Up to 90% RH Non Condensing
  • Electromagnetic Compatibility 
    • Designed in accordance with the following Electromagnetic Compatibility Directives:
      • SI 2005/281 2004/108/EC
  • Case High Impact ABS plastic with tactile membrane keypad
  • Castle Sonus GA116L Class 1 Logging Sound Level Meter
    • GA116LStandards
    • IEC61672-1-2013 (Sound Level Meters)
    • IEC61252-1993 (Personal Sound Exposure Meters)
    • BS4142:2014 Methods for rating and assessing industrial and commercial sound
  • Selectable level ranges on the GA116L:
30-100 29 – 101dB 30 – 100dB 40 – 103dB
50-120 59 – 121dB 50 – 120dB 60 – 123dB
70-140 69 – 141dB 70 – 140dB 80 – 143dB
  • Linear Operating Range 70dB
  • Detector Characteristics RMS and Peak
  • Frequency Weighting ‘A’, ‘C’ & ‘Z’ Weighted in Accordance with IEC 61672-1-2002 Combinations of ‘A’, ‘A’&’C’ simultaneous or ‘A’&’Z’ simultaneous available for Leq, Lmax and Pmax
  • Time Weighting ‘Slow’, ’Fast’ and ‘Impulse’ in Accordance with IEC 61672-1-2002
  • Exchange Rate 3dB, 4dB or 5dB
  • Criterion Level 75dB, 80dB, 85dB or 90dB
  • Threshold Level -5dB, -10dB or OFF
  • Peak 3dB above top of selected range
  • Display Custom alphanumeric LCD, digit size 7mm x 5mm
  • Memory 2100 Data Intervals Maximum
  • Microphone/ Preamplifier ACO 7146A pre-polarised ½” condenser microphone, 25mV / Pa
  • Calibration 91.0 to 120.0dB @ 1KHz
  • Batteries 1 x PP3 (9V) Approximately 12 hours continuous use
  • Operating Temperature Operating Range: -10 to + 50ºC
  • Humidity Effect: < 0.5dB from 25% to 90% RH
  • Vibration No effect on instrument
Castle GA2006H Vexo Tri-Axial Hand Arm Vibration Meter
  • Vexo H Vibration Meter
  • Accelerometer & Accelerometer Cable
  • USB Cable
  • Vexo H Charging Kit
  • VibData Software
  • Vexo H Carrying Case
Castle Sonus GA116L, Class 1 Data Logging Sound Level Meter
  • Sonus GA116L Sound Meter
  • Windshield
  • USB Cable
  • Instruction Manual
  • Free dBDataLite Software


Find Similar Products by Category

Write your own product review

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!

Add to Wish List

Click the button below to add the Castle GA2006H Vibration Meter to your wish list.

You Recently Viewed...